Flush Valves and Cisterns: How Flushing Systems Work
Understand cisterns and direct flush valves, flush inlets, exposed and concealed installations, and the supply and maintenance needs of a complete flushing system.
Basterfield EngineeringUpdated
Flush valve or cistern: what is the difference?
A conventional gravity cistern stores water and releases it into the pan, then refills. A direct flush valve delivers flushing water from the pressurised supply without a separate storage cistern. The practical difference is where the flush water comes from and what the installation must provide during operation.
A cistern also contains an internal flushing mechanism that is sometimes called a flush valve. In this article, direct flush valve means the supply-fed system offered as an alternative to a separate cistern. Keeping the terms clear helps explain why replacing an internal cistern part is a different job from converting the whole flushing arrangement.
Read the complete system as a chain: building supply, control, flush connection, fixture and drainage. The fixture inlet and the water available during use need to match the chosen arrangement. A familiar-looking valve or a shared pipe size is only part of that assessment.
- Gravity cistern: plan the storage unit, flush connection, refill supply and service access.
- Direct flush valve: check operating pressure, available flow, supply pipework and service access.
- For either system, match the flushing arrangement and operating control to the exact fixture.
Top entry and back entry describe the flush inlet
Top entry means flushing water enters through the fixture's top connection. Back entry, also called rear entry, means it enters through a connection at the rear. Match the flushing arrangement to that inlet.
These terms do not describe where fresh water enters a cistern. For example, the B17110(L380-DPB) cistern serves top-entry WC pans but has a side water-supply inlet.
The drainage outlet is another separate choice. Both B17642 pedestal toilet models have back-entry flushing: B17642(P) has a horizontal P-trap waste outlet, while B17642(S) has a vertical S-trap waste outlet. Specify the flush inlet and waste outlet separately.
Exposed or concealed is a separate choice
An exposed installation leaves the valve or cistern on the room side. A concealed arrangement places components behind a wall or within a service space, with an appropriate operating control and maintenance access.
Back entry does not automatically mean concealed. The Walcro 106B is an exposed back-entry valve; the Walcro 103LC is a concealed back-entry valve. Plan how the connections and operating mechanism will be serviced after the wall is finished.
Match the flushing system to your WC pan
The following are catalogue examples. Confirm the exact model, supply requirements and pipe alignment before ordering. Sharing an inlet direction alone does not establish compatibility.
WC flushing options in the Basterfield range:
- Selected fixture: Compatible top-entry pan, such as B17654(PT); Flushing options: B17110(L380-DPB) cistern or Walcro 106T exposed valve; Before ordering: Select one flushing arrangement; the WC pan is separate.
- Selected fixture: B17642(P) or B17642(S), back entry; Flushing options: B17110(L380-CPB) cistern, Walcro 106B exposed valve or Walcro 103LC concealed valve; Before ordering: Choose for the site layout, available services and maintenance access.
- Selected fixture: High-level cistern installation; Flushing options: B17112 high-level cistern with pull rod operation; Before ordering: Confirm fixture compatibility, mounting height and flush pipe.
- Selected fixture: B17656(CTP) close-coupled suite; Flushing options: Includes a stainless steel cistern and internal flushing mechanism; Before ordering: Check the suite contents before adding accessories.
Low-level, high-level and close-coupled cisterns
Low-level and high-level describe the cistern's installation position. Close-coupled describes the cistern and pan arranged together as a suite. Read these descriptions alongside the flushing inlet and drainage details.
The B17110(L380-DPB) and B17110(L380-CPB) are 9-litre low-level cisterns for their respective compatible top-entry and back-entry pans. The B17112 high-level cistern uses a pull rod. The B17656(CTP) suite already includes its cistern and internal mechanism.
Cistern capacity is not confirmation of the delivered volume on every flush. Check the specified flushing volume and settings for the complete cistern-and-pan combination.
Check operating pressure and available flow
Check the maintained-pressure ranges below against the selected Walcro product specification. These are valve-specific figures, not a guarantee that a building supply will flush the selected pan correctly.
Ask the installer to check pressure during operation, available flow and the effect of other fixtures operating at the same time. A static pressure reading alone is insufficient. The nominal inlet size describes a connection; it does not by itself size the building's supply pipework. Match the flushing volume to the fixture's requirements.
Walcro WC valve supply specifications:
- Valve: 106T, exposed top entry; Nominal supply inlet: 25 mm BSP female; Maintained pressure: 30–600 kPa
- Valve: 106B, exposed back entry; Nominal supply inlet: 25 mm BSP female; Maintained pressure: 30–600 kPa
- Valve: 103LC, concealed; Nominal supply inlet: 20 mm BSP female; Maintained pressure: 100–600 kPa
Urinals need their own matching controls
Urinals need their own matching controls and connections. A WC valve should not be assumed suitable for a urinal, and an inlet direction alone does not identify the complete set of parts.
The B17744 bowl range illustrates the distinction: its top-entry and back-entry versions use different listed control and pipe arrangements. The dedicated urinal article explains the connections, component scope and replacement survey in more detail.
Assess the installation as a complete system
For a replacement, begin with a record of what is already installed: fixture model, flushing inlet, waste outlet, control position and connection geometry. Then establish what can be retained. A change from cistern to direct valve can affect the supply requirements even when the pan stays in place.
Maintenance access belongs in the assessment from the start. Imagine removing the operating mechanism or reaching a pipe joint after tiling, panels and cubicles are complete. A neat installation that prevents routine service creates a continuing operational problem.
For a new layout, separate the fixture choice from the building services assessment. The selected product drawing establishes its connection positions; the plumbing design establishes how the required water and drainage services reach them.
Can I replace a cistern with a flush valve?
Possibly, if the fixture, connections and supply suit the proposed valve. Have the installer assess pressure during operation, flow and pipework before choosing a replacement. Check the complete installation rather than assuming the new valve can use the old cistern's supply connection.
Is a flush valve always more water efficient?
Compare the specified flush volume and performance of complete systems. The system type alone does not establish water consumption. An unsuitable setting can leave the fixture needing another flush; do not infer tested consumption from cistern capacity alone.
Are the flushing system and toilet seat included?
Check the selected product's specification. The separate WC pans illustrated here require the flushing system to be specified; the B17656(CTP) close-coupled suite includes its cistern and internal mechanism. Check seat inclusion separately.
Handle orientation is also model-specific. The B17110(L380-DPB) has a right-hand handle as standard; request a left-hand handle when ordering if required.
Keep a record of the installed combination
The useful outcome is a documented combination of fixture, flushing system, operating control and connections that suits the site. Retain model references and service information together so maintenance staff can identify the actual installed parts.
System type alone does not settle water use, compatibility or maintenance effort. Those depend on the complete arrangement and how it is installed, adjusted and looked after.